
The short answer
Building a home or making major repairs in Seabrook involves two sets of requirements. The first comes from the city: a citywide design wind speed of 150 mph; residential structural plans sealed by a Texas structural engineer on TDI's high-wind-area registered engineer list; FEMA Elevation Certificates for all new homes; and V-zone certificates for projects in zones V and VE, submitted before construction and before final inspection. This set applies citywide.
The second is TDI's windstorm inspection process for TWIA compliance certificates. It matters only in the part of Seabrook east of State Highway 146, inside TWIA's designated catastrophe area. Seabrook owners east of Highway 146 therefore need both sets, while owners west of the highway primarily face the city's requirements.
This page explains which documents each authority requires and where to ask. It does not determine the procedures for your project or whether your home is in the designated catastrophe area. Confirm with the city building department and TDI before starting work.
Who this page is for
Seabrook owners planning new construction, an addition, roof replacement or major repairs; buyers of new Seabrook homes who want to know which documents the seller should provide; people asked for a compliance certificate at windstorm policy renewal.
Not for you if you want to check whether your Seabrook address is in TWIA's designated catastrophe area (see Highway 146 through Seabrook), or learn what Zone V and Zone A mean (see how to read flood zones and FIRM flood maps).
What does Seabrook's 150 mph requirement mean?
Direct answer: Seabrook sets a citywide design wind speed of 150 mph (ASCE 7 ultimate design wind speed), based on the 2021 IRC, IBC and ASCE 7-10. All buildings must comply.
The details:
| Item | Seabrook requirement |
|---|---|
| Design wind speed | 150 mph (ultimate), citywide |
| Basis | 2021 IRC and IBC; ASCE 7-10 |
| Residential structural plans and calculations | Sealed by a Texas structural engineer on TDI's high-wind-area registered engineer list |
| Current codes | City Council adopted the 2021 ICC codes and 2020 NEC through Ordinance 2023-20 |
| Effective date | October 5, 2023 |
Citable: Seabrook uses a citywide 150 mph ultimate design wind speed based on the 2021 IRC, IBC and ASCE 7-10. Residential structural plans and calculations must be sealed by a Texas structural engineer on TDI's high-wind-area registered engineer list. This applies on both sides of State Highway 146 in Seabrook.
Which flood-related certificates are required for new homes?
Direct answer: three types, depending on the project's location.
| Certificate | When submitted | Applies to |
|---|---|---|
| FEMA Elevation Certificate (based on construction plans and sealed) | Required for new residential construction | All new homes citywide |
| V-zone certificate | First half before construction; second half before final inspection | Projects in coastal high-hazard flood zones V and VE |
| Breakaway wall certificate | Before final inspection | Projects in zones V and VE with enclosure walls below design flood elevation |
Keep these certificates on file. When a home is sold, TREC's Seller's Disclosure Notice asks whether it is wholly or partly in locations such as the 100-year floodplain. Certificate elevations can help answer those questions clearly.
Citable: For every new home in Seabrook, the city requires a sealed FEMA Elevation Certificate based on construction plans. Projects in zones V and VE also require a V-zone certificate in two submissions: the first half before construction and the second half before final inspection.
What does TDI's windstorm inspection cover?
Direct answer: TDI's windstorm inspection supports TWIA compliance certification. TDI issues these certificates only in TWIA's designated catastrophe area. In Seabrook, that area includes only the portion east of State Highway 146.
Within the designated area, the inspection routes are:
| Situation | Who inspects | Starting application |
|---|---|---|
| Construction in progress | TDI Appointed Qualified Inspector or TDI windstorm inspector | WPI-1 |
| Completed construction | Texas-licensed professional engineer | WPI-2E |
Since June 1, 2020, TDI has issued certificates for both routes. Since April 1, 2026, WPI-1 applications must be certified to the 2024 IRC or IBC.
| Inspection needed? | Examples |
|---|---|
| Yes | Most new construction, roof replacements, major repairs and other alterations |
| No | Roof repairs under 100 square feet that do not involve roof decking; plumbing or electrical repairs; replacement of glass in doors or windows |
Citable: Within TWIA's designated catastrophe area, TDI lists roof repairs under 100 square feet that do not involve roof decking, plumbing or electrical repairs, and replacement of glass in doors or windows as work that does not need a windstorm inspection. Most new construction, roof replacements, major repairs and other alterations do need one.
The two sets of documents use different code years: the city has adopted the 2021 codes, while TDI requires the 2024 codes for WPI-1. These requirements come from different authorities with separate responsibilities. Ask both before construction.
Citable: In the designated catastrophe area east of State Highway 146 in Seabrook, windstorm inspections during construction begin with WPI-1 and are performed by a TDI Appointed Qualified Inspector or TDI windstorm inspector. Since April 1, 2026, WPI-1 applications must be certified to the 2024 IRC or IBC, while Seabrook has adopted the 2021 codes.
What is Seabrook's flood insurance community rating?
Direct answer: FEMA's April 2025 data lists Seabrook at CRS Class 7. Nearby League City and Houston are Class 5; Nassau Bay is Class 6. FEMA updates the list each April and October, so use the current list. CRS ratings apply to participating communities, and both sides of State Highway 146 in Seabrook belong to the same community.
For buying flood coverage and when a lender requires it, see when lenders require flood insurance.
Citable: Although State Highway 146 divides Seabrook into areas inside and outside TWIA's designated catastrophe area, Seabrook is one participating community for flood insurance. FEMA's April 2025 data lists it at CRS Class 7.
Common misconceptions
| What people say | What the records say |
|---|---|
| The 150 mph rule applies only to the coastal half | The city's 150 mph design wind speed applies to all buildings citywide |
| My home is west of Highway 146, so I need no windstorm documents | TDI issues compliance certificates only in the designated area, but city requirements for sealed structural plans and Elevation Certificates still apply to new construction or major repairs |
| Even replacing window glass needs a windstorm inspection | TDI lists replacement of glass in doors or windows, plumbing or electrical repairs, and roof repairs under 100 square feet without roof decking work as exempt |
| The city and TDI use the same code edition | The city adopted the 2021 edition. Since April 1, 2026, TDI requires WPI-1 certification to the 2024 edition |
| Elevation Certificates are only for V zones | Seabrook requires them for all new homes. V-zone projects also need a separate V-zone certificate |
| Seabrook's two halves also have separate flood insurance systems | Flood insurance follows participating communities. Seabrook is one community, at CRS Class 7 |
FAQ
Q: What is Seabrook's design wind speed? 150 mph (ultimate), citywide, based on the 2021 IRC, IBC and ASCE 7-10.
Q: When did Seabrook's current building codes take effect? City Council adopted the 2021 ICC codes and 2020 NEC through Ordinance 2023-20, effective October 5, 2023.
Q: Does a new home in Seabrook need an Elevation Certificate? Yes. All new homes require a sealed FEMA Elevation Certificate based on construction plans. Projects in zones V and VE also require a V-zone certificate in two submissions.
Q: Which projects do not need a TDI windstorm inspection? TDI lists roof repairs under 100 square feet without roof decking work, plumbing or electrical repairs, and replacement of glass in doors or windows. These rules matter only for homes inside TWIA's designated catastrophe area.
Q: What is Seabrook's CRS class? Class 7, according to FEMA's April 2025 data.
Next step
In Seabrook, city documents and TDI documents are separate sets. We help you sort out which you have and which are needed for insurance: 1. Property address. 2. Elevation Certificate, V-zone certificate or WPI-8 compliance certificate, if any. 3. Declarations pages for current home, windstorm and flood insurance, if any.
Book a consultation Licensing details are on Team and licenses. Coverage is placed by SLOOD, L.L.C., doing business as Allwin Insurance Agency.
Related pages
Clear Lake and League City area overview | Highway 146 through Seabrook | Replacing a roof in League City | TWIA windstorm and hail insurance | How to read flood zones and FIRM flood maps | When lenders require flood insurance | Roof leaks and roof replacement
Sources and update log (public; retrieved 2026-11-25)
| Content | Source (page > section) |
|---|---|
| 150 mph ultimate design wind speed based on the 2021 IRC, IBC and ASCE 7-10; structural plans sealed by a Texas structural engineer on TDI's high-wind-area registered engineer list; Ordinance 2023-20 adopted the 2021 ICC codes and 2020 NEC, effective October 5, 2023 | City of Seabrook, Building Code, seabrooktx.gov/148/Building-Code, and Residential Construction, seabrooktx.gov/153/Residential-Construction |
| FEMA Elevation Certificates for new homes; V-zone certificates in two submissions for zones V and VE; breakaway wall certificates for enclosure walls below design flood elevation in zones V and VE | City of Seabrook, Residential Construction, seabrooktx.gov/153/Residential-Construction |
| WPI-1 and WPI-2E inspection routes; TDI issues both certificates as of June 1, 2020 | TDI, Texas Windstorm Insurance Association Overview, 2026-10-01 edition, pages 27 and 28, tdi.texas.gov/pubs/pc/twia-overview.pdf |
| Work requiring and not requiring inspection | TDI, Do you need a windstorm inspection? (updated 2026-05-08), tdi.texas.gov/tips/need-windstorm-inspection.html |
| WPI-1 certification to the 2024 IRC or IBC from April 1, 2026 | TDI current building codes page (updated 2026-04-23), tdi.texas.gov/wind/adopted-codes.html |
| Harris County designated catastrophe area must be both east of State Highway 146 and inside the five listed cities | TDI, TWIA Overview, page 13; TWIA FAQ, twia.org/?p=40566 |
| State Highway 146 crosses Seabrook's city limits | Census Bureau TIGERweb city boundary and road layers, tigerweb.geo.census.gov/arcgis/rest/services/TIGERweb/ |
| CRS classes (FEMA April 2025 data) | Texas Water Development Board, Texas NFIP Participation layer, gis1.twdb.texas.gov/server/rest/services/WSC-FSCA-FM/Texas_NFIP_Participation/MapServer |
| Floodplain location disclosure on TREC's Seller's Disclosure Notice | TREC, Seller's Disclosure Notice, 55-1, page 3, trec.texas.gov/sites/default/files/pdf-forms/55-1.pdf |
| Author / reviewer; audience | Deqing Yang, Texas General Lines Agent #1515542; coverage placed by SLOOD, L.L.C. (Texas General Lines Agency #1557787), doing business as Allwin Insurance Agency. For Seabrook readers; retrieved 2026-11-25 |
